Data centers have much to learn there are places in the Shi Ji applications we will encounter some problems, here we introduce Ruhe solve data center 非 standard equipment EDA Circuit Connection Patterns, from the flexibility, high-density, high reliability, easy to use of a comprehensive exposition of the aspects of the problem.
Data traffic in today's fast-growing data center room will be the unprecedented scale of construction, many large data centers in the room in order to support efficient data processing, typically use more non-target server devices or storage devices, The so-called non-standard equipment refers to equipment installed outside the network size does not meet the standard specifications of the transmission equipment cabinets. Popular to say, non-standard equipment EDA wiring installed in the room can not be a standard 19-inch network cabinet, non-standard equipment is usually their own chassis and directly placed in the floor event room. Data center cabling in accordance with the usual standard, EDA area (equipment wiring area) is classified in the equipment cabinet, but for the whole cabinet is a non-standard equipment, transmission equipment, the wiring is clearly not in the usual way, within the non-standard equipment has not only put wiring space, then the actual wiring works, how we can achieve neither the data center structured cabling against the relevant standards, but also the embodiment of good non-standard equipment EDA layout area routing flexibility, high density , reliability, ease of use these features?
Routing technique developed in recent years, has been quite different than a few years ago. In the routing area by the manufacturers showed further specialization, in addressing non-standard minicomputer equipment EDA wiring issue, Germany and France Kabo Fei Rosenberg companies and pioneered the integration of the bridge The concept of aircraft wiring, minicomputers in the non-standard equipment under the floor above the bridge or bridge can be easily combined into one MDF and the bridge.
This is an innovative design of the patch panel products are Germany, Rosenberg companies named Hybrid-Patch light copper hybrid modular patch panels, fully demonstrate the flexibility, high density, reliability, ease of use with line product features, especially the data center cabling wiring non-standard equipment EDA, and more unique elements.
Flexibility
End data center equipment can usually configure the network card light card can also configure the copper, and equipment and specific applications of two different port number is not a defined value, which requires wiring products have specific requirements under the flexible configuration, Hybrid -Patch by using a modular structure, can be divided into different modules, each module can install the appropriate number of modules, such as temporary do not install the module, you can cover with blind holes blocked. Commonly used in the patch panel modules can be divided into three types, one type RJ45 module, RJ45 module can be installed for each 12 RJ45 modules, the other is the LC type optical fiber modules, each module can LC 24-core optical fiber wiring installation, there are special requirements for high density applications, can provide MPO modules, each module can be installed on 96 core MPO fiber wiring, different or the same module can be installed on the Hybrid-Patch patch panel, each patch panel can accommodate up to three of these modules. The feature product is the whole DIY concept into the design process, to fully ensure the non-standard equipment, the configuration requirements of a Hybrid-Patch while addressing the fiber-optic and copper wiring requirements. MDF and other accessories that comes with the installation of bridge, the patch panel itself can be easily installed in standard 19-inch cabinets, fully reflected in the practical application flexibility.
High density
Room layout and general wiring applications compared to one of the most obvious features of high-density, Hybrid-Patch light copper hybrid modular patch panel is the standard overall height of space 1HU, the product name suggests can be configured fiber products and copper products, 1HU itself contains high levels of line management device, compared with the traditional, this part of the design already, is equivalent to doubling the density of the other, all the configuration port on the patch panel RJ45 copper ports, up to 36 with the traditional level of management without the thread of 24 compared to copper patch panel, equivalent to 3 times the density increases. If all the interfaces with LC optical interface, up to 72 cores. If the EDA is particularly high density fiber optic cabling, Hybrid-Patch MPO optical interface can be used on a patch panel in general can reach 288 core, it only takes up 1HU density of the high space.
High reliability
Wiring in the data center program, Hybrid-Patch program and other wiring products can be seamlessly butt, especially applicable to the data center was recommended pre-wiring to connect cables supporting the use of, and the overall and Hybrid-Patch matching products, increased performance and reliability of a rating. Also in the Hybrid-Patch products specially designed lock installation and maintenance, installation and maintenance lock can be kept by the maintenance staff, and only in the engine room when the installation and maintenance by authorized maintenance personnel to deal with, the details of the design is of the product life-cycle management and maintenance of security and reliability. In the product details on the design of fully reflect the requirements of reliability, respectively, in patch panel design on both sides of curved offline devices, offline device is based on the bending radius of patch cord bend radius standards to design, mainly to protect the security of cable off the assembly line office will not be offline due to high density when the pressure in the end both sides of the Department of fiber optic cable bend radius is too small, leading to the phenomenon.
Ease of use
No matter how excellent product performance parameters, for users, ease of use and practicality are very important factors, from the Hybrid-Patch can see many details can reflect the characteristics of practical use. In addition to the patch panel on the level of integrated management thread of the function, the first surface with a rotating bezel panel to maintain the label, the label panels can easily make a clear identification records, to this point for high-density wiring products, it is not easy to achieve, but for the subsequent maintenance and management is an important thing, Hybrid-Patch panel with rotating label design approach, a better balance between a high both density and easy to manage product requirements of the wiring. Wiring for non-standard equipment for the EDA, as Hybrid-Patch is installed in the cabinet above or below the bridge on the floor activities, EDA wiring can not occupy the space equipment rack does not need any extra wiring space, and bridge one each other, reflect the usefulness and ease of use routing principles.
The core equipment in the data center progress of the technology for space and further increase in equipment performance, while the space occupied by smaller and smaller, as U.S. researchers said SUN, 20 years ago, the size of a standard server equipment container performance is not as high now the size of a network server cabinet. Network Equipment technical progress, while the technology also requires wiring simultaneous development, the specialized division of labor is now more sophisticated, the field wiring changes are taking place quietly, Rosenberg represented the German company is constantly upgrading wiring for in the data center room of the professional product solutions, product development principle is to meet and exceed existing industry standards, Hybrid-Patch The launch of the data center room Rosenberg professional product line in one of them.